The comparison can only be displayed from a display size of at least 1024 pixels
Please use an alternative display device.
Compare our AccuMind® with your flow computer
We have summarized the most important points for you in a fair market overview.
AccuMind®
Display content:
|
free choosable (1-6 values, TAG-No.) |
Display type:
|
TFT-color display 16:9; 480 Pixel × 272 Pixel |
Handling:
|
capazitive touchscreen |
Data logging:
|
all values on USB stick, number limited by memory capacity |
Digital transmission of the HART signal of differential pressure transmitters to extend the measuring range?
|
yes, flowsignal via HART |
Bidirectional measurement:
|
yes, with 1 DP-transmitter (via HART without loss of accuracy) |
Correction of linearity error of flow transmitter:
|
yes |
Technical gases with all relevant parameters:
|
freely configurable, also for wet gases incl. signal input for humidity |
Calculation of properties of natural gases:
|
AGA-3, AGA-8, AGA-NX 19, SGERG-88, others on request |
Consideration of calibration results dependig on the reynolds number:
|
up to 10 points |
Error monitoring of the connected sensors:
|
yes (error curents acc. to NAMUR; monitoring of the Pt100) |
E+H RMS 621
| free choosable |
| 160 x 80 DOT-Matrix LCD |
| via 8 soft keys |
| (not specified) |
| no |
with 1 (splitted signal) or 2 dp transmitters |
| yes |
| no |
| no |
| no |
|
yes (error curents acc. to NAMUR)
|
E+H RMC621
| free choosable |
| 160 x 80 DOT-Matrix LCD |
| via 8 soft keys |
| (not specified) |
| no |
with 1 (splitted signal) or 2 dp transmitters |
| yes |
limited scope, no wet gases |
| AGA-8, AGA-NX 19, SGERG-88 |
| no |
|
yes (error curents acc. to NAMUR)
|
Contrec 515
one measured value, choosable |
| two-line LCD display |
| 5 membrane keys |
| over 1000 entries |
| no |
| no |
| yes |
input option for: - specific gravity - critical temperature - critical pressure |
AGA and SGERG choosable |
only depending on the analog values |
|
cable break is checked
|
Systec Flowcom
| max. two measured values, choosable |
| two-line LCD display |
| 5 membrane keys |
| up to 2600 entries |
| no |
yes, with 2 dp transmitters |
| yes |
partially yes, via tables for Air, N2, CO2, CH4, O2, H2 |
| GERG-88 |
| no |
| yes (standards not specified) |
METRA ERW 700
| two measured values, with TAG No. |
| LCD display |
| 4 membrane keys |
ring memory for appr. 1000 values of different kinds |
| no |
yes, with 2 dp transmitters |
| yes |
Ideal gas and Redlich-Kwong, based on own methods |
calculated according to internally stored methods. Special media with polynomial coefficients. |
| yes |
| cable break, etc. is checked) |
S.K.I. µFlow
two to three measured values, choosable |
| two-line LCD display |
| 5 membrane keys |
| no |
| no |
| no |
| no |
| limited |
| AGA NX 19 |
| no |
| no |
INTRA Digiflow 515
one measures value, choosable |
| two-line LCD display |
| 4 membrane keys |
| no |
| no |
with 1 (splitted signal) dp transmitter for both directions |
| (not specified) |
| Redlich-Kwong |
| AGA-NX 19 mod |
| no |
| yes (error currents) |
ABB Sensycal
one measures value, choosable |
| LCD-Display |
| 3 membrane keys |
| 20 values, 200 periods |
| no |
| no |
flow coefficient and expansion number correction |
| via real gas factor |
| no |
| no |
yes (measured value out of range, sensor break, etc.) |
The AccuMind®. Developed by users for users.