Air Purging Device

SDF flow sensors are highly resistible against negative effects caused by heavy dust loads in flue gases. However it is possible that particle deposits at the sensor occur at high dust concentrations or low flow velocities. The air purign device LSE-HD scavenges these deposits even at extrem dust loads within the medium in a reliable way.

The unique allows the separate flush of both chambers of the flow sensor. In addition to that the LSE-HD can support the flushing effect by a high allowed purging air pressure: the intenal parts are designed for a pressure gauge of 100 bar.

To avoid trouble with a downstream controlling system the LSE-HD provides the storage of the measured value during the purging is in progress. During this time an autoamatic offset control is performed. An alarm occurs if the adjustable limit values of the zero point offset are exceeded.

As an option the internal controller of the LSE-HD can provide the standardisation of the volume flow (ref. point 0°C; 101,325 kPa abs.).

 

 

Highlights in short form:

  • high purging effect by separate flushing of both sensor chambers
  • high purging effect by large internal diameters of the pressurised air lines
  • high purging effect by high allowed air pressure
  • Storage of the measured value during purging in progress
  • Automatic zero point offset control
  • Optional: calculation of the standard volume flow